A sensitive fluoroimmunoassay for quantitative detection of imidacloprid based on quantum dot-streptavidin conjugate

Talanta. 2024 Apr 18;275:126128. doi: 10.1016/j.talanta.2024.126128. Online ahead of print.

ABSTRACT

Imidacloprid (IMI), the most commonly used neonicotinoid, is widely present in both the environment and agro-products due to extensive and prolonged application, posing potential risks to ecological security and human health. This study introduced a sensitive and rapid fluorescence-linked immunosorbent assay, employing Quantum Dot-Streptavidin conjugate (QDs-SA-FLISA), for efficient monitoring of IMI residues in agro-products. Under optimized conditions, the QDs-SA-FLISA exhibited a half-maximal inhibition concentration (IC50) of 1.70 ng/mL and a limit of detection (LOD, IC20) of 0.5 ng/mL. Investigation into the sensitivity enhancement effect of the QDs-SA revealed that the sensitivity (IC50) of the QDs-SA-FLISA was 7.3 times higher than that of ELISA. The recoveries and relative standard deviation (RSD) ranged from 81.7 to 118.1 % and 0.5-9.4 %, respectively, for IMI in brown rice, tomato and pear. There was no significant difference in IMI residues obtained between QDs-SA-FLISA and UHPLC-MS/MS. Thus, the QDs-SA-FLISA represents a reliable approach for the quantitative determination of IMI in agro-products.

PMID:38657361 | DOI:10.1016/j.talanta.2024.126128